Privacy note: We capture your IP address to provide customised and focused services. See our Privacy Policy.

AP Physics 1: Deep Dive — Alpha School

Lesson 15: Uncertainty, Error and What a Result Really Means

Random and Systematic Errors

Every measurement has uncertainty, and the first step is to know which kind you are dealing with. Random errors vary from one measurement to the next: your reaction time when starting a stopwatch, or the small wobble of a ruler. They can be reduced by taking repeats and averaging. Systematic errors shift every measurement the same way: a ruler with a worn end, a stopwatch that runs slow, or a length measured from the wrong point. Repeats do nothing for systematic errors, because every repeat carries the same shift.

The distinction decides the fix. Random errors are found by repeating and looking at the spread; systematic errors are found by checking the apparatus against a known standard, or by using a different method and comparing. A result quoted without an uncertainty is incomplete: it claims more precision than the experiment can support. Always ask how big the uncertainty is, and whether it is random, systematic, or both.

Worked example: a student times ten swings of a pendulum five times and gets 20.1, 20.4, 19.8, 20.2 and 20.3 s. The mean is 20.16 s, and the spread is about 0.2 s, so the period is 2.016 s with an uncertainty of roughly 0.02 s from the spread. But the reaction time of 0.2 s on the total time is a systematic effect that does not shrink with repeats in the same way: starting and stopping the watch late by the same amount cancels, but starting late and stopping early does not. The honest uncertainty statement combines both: the random spread from the repeats and the systematic limit of the timing method. Quoting the period to four significant figures would be dishonest, because the method cannot support it, while quoting it as 2.02 plus or minus 0.03 s says exactly what the experiment can claim.

An uncertainty statement is also a promise about what the experiment cannot say. A period measured as 2.02 plus or minus 0.03 s cannot distinguish between two models whose predictions differ by 0.01 s, and claiming otherwise would be over-claiming. That honesty is what makes a result trustworthy.

Absolute and Percentage Uncertainty

Uncertainty can be stated as an absolute value, such as 2.0 plus or minus 0.1 s, or as a percentage, such as 5 percent. Percentage uncertainty is the absolute uncertainty divided by the measured value, times 100. It is the useful form when you combine measurements, because percentage uncertainties add when quantities are multiplied or divided, while absolute uncertainties add when quantities are added or subtracted.

Worked example: a length of 0.50 m measured with a ruler that reads to plus or minus 0.01 m has a percentage uncertainty of 2 percent. A time of 20 s measured with a stopwatch uncertain by 0.2 s has a percentage uncertainty of 1 percent. If the result depends on length divided by time squared, the percentage uncertainty is roughly 2 percent plus twice 1 percent, which is 4 percent. The factor of two appears because the time is squared. This is how you judge whether a result is precise enough to support a conclusion.

What Counts as Agreement

A measured value agrees with a theory if the theory's value lies inside the measurement's uncertainty range, not if the two numbers are identical. A measurement of g as 9.5 plus or minus 0.6 m/s squared agrees with the accepted 9.8, because 9.8 falls inside the range from 8.9 to 10.1. A measurement of 9.5 plus or minus 0.1 does not agree, because 9.8 lies outside 9.4 to 9.6, and that disagreement is itself a result: it says something is wrong with the method or the model.

When two measurements disagree beyond their uncertainties, do not hide the disagreement. Report it, and suggest a cause: a systematic error, a control variable that drifted, or a model that does not apply in the range used. That honest discussion is worth more than a perfect-looking number, because it shows you understand what the experiment actually measured.

Key Terms

Random error
An error that varies between measurements; reduced by repeats and averaging.
Systematic error
An error that shifts all measurements the same way; repeats do not remove it.
Absolute uncertainty
The uncertainty stated in the same units as the measurement, such as plus or minus 0.1 s.
Percentage uncertainty
The absolute uncertainty as a percentage of the measured value.
Outlier
A measurement far from the others, usually from a mistake; it should be investigated, not silently deleted.
Agreement
When a theoretical value falls inside a measurement's uncertainty range.

Discussion Questions

  1. Why do repeats help with random errors but not with systematic errors?
  2. A value of g is measured as 9.5 plus or minus 0.6. Does it agree with 9.8? Why?
  3. Why is a result without an uncertainty incomplete?

Practice Questions

  1. A length of 0.50 m has absolute uncertainty 0.01 m. What is its percentage uncertainty?
  2. A time of 20 s has uncertainty 0.2 s. What is its percentage uncertainty?
  3. Name one random error and one systematic error in timing a pendulum.
  4. Why should an outlier be investigated rather than silently deleted?
  5. What does it mean if a measured value disagrees with theory beyond its uncertainty?
Show answers
  1. 2 percent, from 0.01 divided by 0.50 times 100.
  2. 1 percent, from 0.2 divided by 20 times 100.
  3. Random: reaction time starting the stopwatch. Systematic: a stopwatch that runs slow.
  4. Because it may reveal a mistake in the method, and deleting data without a reason is not honest science.
  5. That something is wrong with the method or the model, and the disagreement itself is a result to report.
Keep reading to complete this lesson